B2026-093 Fixed a null reference error that happened when opening an alarm point page for the first time #836
@@ -3663,6 +3663,8 @@ namespace Volian.Controls.Library
|
||||
TabLeft = 20;
|
||||
if (!itemInfo.IsStep) // C2025-036 reduce un-needed processing - this will prevent duplicat calls that generate step tabs when loading a procedure
|
||||
SetupHeader(itemInfo);
|
||||
//B2026-093 move the setting of MyStepPanel to fix null reference error when the Alarm Point Table is first setup for the editor view
|
||||
MyStepPanel = myStepPanel;
|
||||
SetupAlarmTableView(itemInfo); // C2021-018 display alarm point table information in the step editor (if the format flag is set)
|
||||
this.Paint -= new PaintEventHandler(EditItem_Paint);
|
||||
this.Paint += new PaintEventHandler(EditItem_Paint);
|
||||
@@ -3707,7 +3709,6 @@ namespace Volian.Controls.Library
|
||||
if (myStepPanel.MyFont != null) ContentFont = TabFont = myStepPanel.MyFont;
|
||||
}
|
||||
if (expand) ShowExpanded();
|
||||
MyStepPanel = myStepPanel;
|
||||
if (itemInfo != null && !myStepPanel._LookupEditItems.ContainsKey(itemInfo.ItemID)) myStepPanel._LookupEditItems.Add(itemInfo.ItemID, this);
|
||||
_MyChildRelation = myChildRelation;
|
||||
if (myParentEditItem != null) RNOLevel = myParentEditItem.RNOLevel;
|
||||
|
||||
Reference in new issue