Compare commits

..

2 Commits

Author SHA1 Message Date
1c56aa2eb1 B2026-011 Improve the resolution of unit numbers in multi-unit background documents when printing.
Multi-Unit Background documents --- Found this while looking at background Documents for Vogtle 3/4 --- particularly AOP-101 -> Operator Actions -> Step 2: Note 2.

When there is a unit designator (like <U-NAME>-AOP-101. ) in the note's text, PROMS renders the text and pulls it over as text only to the background document.

This causes printing the background document to print as if both units instead of resolving if a specific unit is being printed.
2026-02-03 13:30:30 -05:00
f38aa4595f Merge pull request 'C2026-062 When Search clicked - Load the Incoming transitions for the Active Procedure' (#699) from C2026-062 into Development
good for testing
2026-02-02 15:54:50 -05:00

View File

@@ -3312,6 +3312,25 @@ namespace VEPROMS.CSLA.Library
return retval; return retval;
} }
} }
//B2026-011 Improve the resolution of unit numbers in multi-unit background documents when printing.
// for enhanced documents, when copying content, need to not resolve the
//unit designators until print time
public string DisplayTextKeepSpecialCharsKeepUnitSpecific
{
get
{
string str = MyContent.Text;
foreach (string key in SpecialCharacters.Keys)
str = str.Replace(key, SpecialCharacters[key]);
string retval = ConvertToDisplayText(str);
foreach (string key in SpecialCharacters.Keys)
retval = retval.Replace(SpecialCharacters[key], key);
return retval;
}
}
public string DisplayNumber public string DisplayNumber
{ {
get get
@@ -8358,7 +8377,10 @@ namespace VEPROMS.CSLA.Library
{ {
ItemInfo srcItem = ItemInfo.Get(seds[0].ItemID); ItemInfo srcItem = ItemInfo.Get(seds[0].ItemID);
// B2022-049: Copy/paste of enhanced procedure and bad links between source and enhanced. Null reference check // B2022-049: Copy/paste of enhanced procedure and bad links between source and enhanced. Null reference check
if (srcItem != null && srcItem.DisplayTextKeepSpecialChars != ii.DisplayTextKeepSpecialChars) //B2026-011 Improve the resolution of unit numbers in multi-unit background documents when printing.
// for enhanced documents, when copying content, need to not resolve the
//unit designators until print time
if (srcItem != null && srcItem.DisplayTextKeepSpecialCharsKeepUnitSpecific != ii.DisplayTextKeepSpecialCharsKeepUnitSpecific)
{ {
if (retiil == null) retiil = new ItemInfoList(ii); if (retiil == null) retiil = new ItemInfoList(ii);
else retiil.AddItem(ii); else retiil.AddItem(ii);
@@ -8384,7 +8406,10 @@ namespace VEPROMS.CSLA.Library
ItemInfo srcItem = ItemInfo.Get(seds[0].ItemID); ItemInfo srcItem = ItemInfo.Get(seds[0].ItemID);
using (Item enhItem = Item.Get(ii.ItemID)) using (Item enhItem = Item.Get(ii.ItemID))
{ {
enhItem.MyContent.Text = srcItem.DisplayTextKeepSpecialChars; //B2026-011 Improve the resolution of unit numbers in multi-unit background documents when printing.
// for enhanced documents, when copying content, need to not resolve the
//unit designators until print time
enhItem.MyContent.Text = srcItem.DisplayTextKeepSpecialCharsKeepUnitSpecific;
enhItem.Save(); enhItem.Save();
} }
} }