bd7204aff8
B2017-093: Pagination issue when no supplemental information on page or when 2 steps on page & only 2nd has supplemental information
2017-05-24 12:34:42 +00:00
4f5585e332
B2017- 092 Added logic to the PDF generation so that duplicate PDF Bookmarks are not added for steps containing supplemental information.
2017-05-22 15:33:41 +00:00
68aa1e9aab
B2017-091The Checkbox for inserting blank pages for duplex printing was shortened so that it does not run into the Cancel button. It now reads “Add Blank Pages For Duplex Printing”. Also when print a procedure that has facing pages this check box is checked by default.
...
B2017-090 Commented out a line of code that is no longer needed for printing facing pages, but was causing the main procedure to paginate incorrectly.
Sped up the logic that calculates how small to shrink the font size on the supplemental information facing page.
2017-05-22 15:32:47 +00:00
8280de55e2
First round of reducing the font size of supplemental info text if would not normally fit on a page
2017-05-18 16:27:09 +00:00
7f4173af82
Logic to keep the supplemental info pages in sync with the SAMG procedure should the sup info print past the end of the page
2017-05-18 16:26:17 +00:00
bbbcdf946a
Add text to checkbox for blank page printing
...
Improve pagination for SAMG facing page print
2017-05-12 13:50:02 +00:00
f139c79d32
Support for SAMGS Supplemental Information
2017-05-03 14:37:25 +00:00
f5c4d24cf7
2017-04-13 19:01:28 +00:00
Rich
ff47bd858b
Fixed logic to Copy Search Results to eliminate duplicate steps in the results
...
Fixed logic to Print Search Results to eliminate duplicate steps in the results
Fixed logic to prooperly output the procedure number and title
2017-04-12 14:48:11 +00:00
b8f330718e
B2017-046 added a check for a zero selection length when we check a table cell that uses the symbol font
2017-03-16 19:28:38 +00:00
Rich
7517636273
Added Comment
2017-03-02 15:18:33 +00:00
Rich
a958f403d8
B2017-036 - Fixed logic to account for Section Continue Message. Found in Automated Testing
2017-03-02 15:14:28 +00:00
4686cb0f6e
Added a check for column mode before adjusting a sub-step note or caution text width
2017-02-16 17:09:52 +00:00
0f99ac59f5
F2017-011 fixed logic that was partially overwriting the text in the TitleWithTextRight step type (enhanced backgrounds) Also fixed the positioning of the TitleWithTextRight and TitleWithTextBelow step types on the step editor for enhanced backgrounds
...
null reference check
F2017-013 – added logic to SplitTitle to handle when the page list item containing <SectionLevelTitle> also has text (ex: <SectionLevelNumber>) on the same line and we need to split all of that text onto another line
2017-02-08 20:19:28 +00:00
8d1babe2cd
B2017-019 use DisplayNumber and DisplayText on the table of contents so that <u> will get translated
2017-01-30 19:45:09 +00:00
54765cea95
F2016-061: Additional signoff types for VCBA & WST1 for SCANA’s maintenance department
2017-01-24 16:00:06 +00:00
bfc321abbf
B2016-269: Ginna – notes on sub-steps were printing beyond the margin and off the page
2017-01-10 14:36:34 +00:00
929d027394
B2016-277: don’t crash on bad data in text field for a figure
2016-12-07 13:57:49 +00:00
a9bd84ad5f
B2016-273: checkoff/signoff for embedded images
...
B2016-272: centered tables print too far to right
2016-12-05 13:55:57 +00:00
Rich
10508fef5f
B2016-266 Fixed pagination logic for Section Continue Message
2016-12-01 16:01:38 +00:00
e27bbff7d8
Fix B2016-270: centered equations (one below another) don’t print centered
...
Fix B2016-259: centered table off centered table was not centered in print (add ‘TableCenterPos’ values)
2016-12-01 13:40:15 +00:00
3a2759470d
check for null reference when deleting a source step that has associated enhanced (found during fix for B2016-228)
...
B2016-228: when creating section/procedure enhanced items, set ‘Number’
B2016-228: when modifying source section or procedure, save ‘Number’ also
B2016-198: User hold point no longer overwrites the ‘INIT/DATE’ signoff heading
2016-11-29 13:52:43 +00:00
1ff60597c3
B2016-262 & B2016-263: for search results & report, print ‘Equation’ for Document text rather than rtf
...
Additional functionality for Equation Editor, bring up equation editor tool (from registry setting) on Equation button click
B2016-265, print proper size of change bar
B2016-261: don’t print extra blank lines for a table/equation/figure after caution/note off many lined step in single column mode
2016-11-22 14:16:04 +00:00
0b7371367c
Equation Editor interface support
2016-11-17 15:05:15 +00:00
Rich
ac126563df
All - B2016-247, B2016-251 Complete RO Report Issues:
...
Underscore in Iamge File Name was being converted to Underline command
Double Underscore was being remove from group headings This was corrected to change double underscore to a space.
Empty fields were causing the code to crash and print only a small portion of the report
2016-11-10 16:50:24 +00:00
Rich
c014652d90
Keep RO Link for RO Images
...
Changed AddRtfText to public
Center figures in the PDF
Added debug output for figures.
2016-11-04 13:22:54 +00:00
Rich
f65d364f57
Summer Management Directives should have a Unit Designator of NSBU
2016-11-03 13:25:54 +00:00
e689dc2ba0
Embedded images
2016-10-17 14:25:30 +00:00
Rich
49ced60b22
Procedures with numbers that start with VC2 will be identified as pertaining to Unit 2
...
Procedures with numbers that start with VC3 will be identified as pertaining to Unit 3
2016-10-14 19:57:19 +00:00
Rich
4266d2fef0
Account for Section Continue Messsage when doing pagination
2016-10-05 17:40:02 +00:00
454697efdf
B2016-222 fixed calculation of box height for notes and cautions at a section level
...
Added a check to prevent an index out of range error
2016-10-04 19:13:11 +00:00
ba5736d19a
Fix B2016-219: VC Summer’s centerline prints on top of figure
2016-09-28 16:15:10 +00:00
Rich
1926a435b0
Replace <u> within a PC P/C PSI Value with the current unit number.
2016-09-27 19:35:36 +00:00
570404687c
B2016-216 Don’t put a page break between a group heading and the first item under it.
2016-09-27 19:18:01 +00:00
6f16095159
F2016-033: Replace “User Hold Point” with “Verification Point” step type & support its printing
...
F2016-042: Fix tabbing of section text location (was overwriting number)
2016-09-27 13:04:35 +00:00
Rich
234682420f
If the Printable Text - X Location is set for an annotation Type and text is entered in the annotation between square brackets, the text will be displayed next to the step with the annotation. This is limited since there mat not be much space next to the step. The location is in points (1/72 of an inch, 36=> 1/2 inch, 18=> 1/4 inch). Also Up and Down arrows can be included in this text, by typing {Up} and {Down} within the square brackets.
2016-09-26 21:11:28 +00:00
73daac2ce1
F2016-039: fix text column widths when a checkoff is used for vcb formats.
2016-09-26 13:50:03 +00:00
Rich
5b25cf6d6c
Added code so that Means can be printed properly.
2016-09-23 14:43:42 +00:00
Rich
41ec066d69
Fixed logic to account for the Section Continue Message at the top of the page.
2016-09-22 14:06:30 +00:00
Rich
65d9e6231d
Added support for VCB Unit Numbers
2016-09-16 15:22:27 +00:00
6a737a961d
Fix for auto TOC grouping logic (B2016-200) and for line spacing consistency (B2016-205)
2016-09-12 18:47:05 +00:00
36e4b0c3ab
Added check for even page number before printing Auto Table of Contents to determine if blank page should be printed. B2016-181
2016-09-06 19:33:14 +00:00
Rich
30c7c16cd0
Fix the RTF for grid cells so that Text is set to use a Text font rather than a Symbol font.
...
Added some debug code for testing the function above. After the code was finished, the debug code was commented-out.
2016-08-19 15:31:43 +00:00
Rich
948161603a
Set the default text font based upon the current format for Tables.
2016-08-19 15:30:04 +00:00
0804ecc7ee
B2016-174: PartialStepCompression does not work correctly for Background formats (those steps that use PageBreakOnStep format flag)
2016-08-09 11:37:12 +00:00
a2835ab73d
Added Warning with triple line box, Adjusted PSI Use Class text X-location
...
Support for Printing ‘[xx]’ text within an annotation by allowing for xlocation on dialog.
Triple Line Box around note or caution
2016-08-04 10:35:26 +00:00
146e1fb968
New Table of Contents flags & MaxWidth for PSIs (for current page)
...
Improve message when format is changed and not certain if section type is valid. (part of B2016-165)
vcb1: Added MaxWidthCurPage for PSI text widths (use for current page)
vcb1: Table of Contents values for subsections line spacing and grouping section numbers
Table of Contents to handle single space subsections & Grouping section names remove group title
Use MaxWidthCurPage to handle max width, but don’t account for multiple lines when printing content
2016-07-25 15:04:23 +00:00
cc927d1cd5
Meta section printing: pagelist headers, page counts
...
Meta section printing: xoffset for sub/subsections, pagelist headers, page counts; start title page classification box
2016-07-18 14:00:37 +00:00
6a1c9473a5
B2016-168: Deviation Document printing: column widths were not wide enough
2016-07-15 11:16:50 +00:00
85ea4d6efb
fixes B2016-166: calvert pagination for complicated AER/RNO page break
2016-07-14 11:44:13 +00:00