Merge pull request 'C2026-023 Change "Applicability - Set All at Level" to check the transitions at each level for steps that would be changed.' (#718) from C2026-023 into Development
good for testing
This commit was merged in pull request #718.
This commit is contained in:
@@ -5,6 +5,7 @@ using System.Collections.Generic;
|
||||
using System.ComponentModel;
|
||||
using System.Data;
|
||||
using System.Drawing;
|
||||
using System.Linq;
|
||||
using System.Text;
|
||||
using System.Windows.Forms;
|
||||
using VEPROMS.CSLA.Library;
|
||||
@@ -284,10 +285,17 @@ namespace Volian.Controls.Library
|
||||
Volian.Base.Library.BigNum MasterSlave_ApplicabilityTmp;
|
||||
StepConfig sc = MyItemInfo.MyConfig as StepConfig;
|
||||
MasterSlave_ApplicabilityTmp = sc.MasterSlave_Applicability;
|
||||
StringBuilder sb = new StringBuilder();
|
||||
|
||||
|
||||
ItemInfo startitm = MyItemInfo.FirstSibling;
|
||||
while (startitm != null)
|
||||
{
|
||||
|
||||
// C2026-023: Check for Transitions when setting Applicability to all for a level
|
||||
List<InvalidTransition> invalidTrans = WillTransitionsBeValidCommand.Execute(startitm.ItemID, MasterSlave_ApplicabilityTmp.ToString());
|
||||
if (IsProcWithNoExternalTrans(startitm, invalidTrans))
|
||||
{
|
||||
StepConfig sc2 = startitm.MyConfig as StepConfig;
|
||||
using (Content cnt = Content.Get(startitm.MyContent.ContentID))
|
||||
{
|
||||
@@ -295,11 +303,34 @@ namespace Volian.Controls.Library
|
||||
cnt.Config = sc2.ToString();
|
||||
cnt.Save();
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
if (sb.Length == 0)
|
||||
{
|
||||
sb.AppendLine("The applicability for some Step(s) cannot be changed due to transition links.");
|
||||
sb.AppendLine("Applicability settings for these steps will return to original settings when OK is selected.");
|
||||
sb.AppendLine("Changing the applicability for would invalidate a transition in the following steps:");
|
||||
sb.AppendLine();
|
||||
}
|
||||
|
||||
foreach (InvalidTransition inv in invalidTrans.Where(x => !x.TgtStep.StartsWith(x.SrcStep)))
|
||||
{
|
||||
sb.AppendLine(string.Format("{0} : From {1} to {2}.", startitm.MyTab.CleanTextNoSymbols.Trim(), inv.TgtStep, inv.SrcStep));
|
||||
}
|
||||
|
||||
invalidTrans.Clear();
|
||||
}
|
||||
|
||||
startitm = startitm.GetNext();
|
||||
}
|
||||
|
||||
_MyDisplayTabItem.MyStepTabPanel.MyStepTabRibbon.RefreshProcedure();
|
||||
|
||||
if (sb.Length > 0)
|
||||
FlexibleMessageBox.Show(sb.ToString(), "Transitions Affected By Applicability Change");
|
||||
|
||||
|
||||
}
|
||||
|
||||
// B2021-149: for procedure, only consider external transitions as invalid
|
||||
|
||||
Reference in New Issue
Block a user