From 1f74f7673b7f821c9ca7f5938a2fc3f10b4ab201 Mon Sep 17 00:00:00 2001 From: Kathy Date: Thu, 4 Oct 2012 11:20:03 +0000 Subject: [PATCH] --- .../Extension/AuditExt.cs | 28 +++++++++++++++---- .../Extension/ContentExt.cs | 1 + .../Extension/DocumentExt.cs | 2 ++ 3 files changed, 25 insertions(+), 6 deletions(-) diff --git a/PROMS/VEPROMS.CSLA.Library/Extension/AuditExt.cs b/PROMS/VEPROMS.CSLA.Library/Extension/AuditExt.cs index 5dd4134f..3a6b75eb 100644 --- a/PROMS/VEPROMS.CSLA.Library/Extension/AuditExt.cs +++ b/PROMS/VEPROMS.CSLA.Library/Extension/AuditExt.cs @@ -239,6 +239,7 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getAnnotationAuditsByItemID"; cm.Parameters.AddWithValue("@ItemID", criteria.ItemID); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; @@ -297,6 +298,7 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getAnnotationAuditsByAnnotationID"; cm.Parameters.AddWithValue("@AnnotationID", criteria.AnnotationID); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; @@ -361,6 +363,7 @@ namespace VEPROMS.CSLA.Library cm.CommandText = "getAnnotationAuditsChronologyByItemID"; cm.Parameters.AddWithValue("@ProcItemID", criteria.ProcItemID); cm.Parameters.AddWithValue("@ItemID", criteria.ItemID); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; @@ -437,6 +440,7 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getContentAuditsByContentID"; cm.Parameters.AddWithValue("@ContentID", criteria.ContentID); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; @@ -508,6 +512,7 @@ namespace VEPROMS.CSLA.Library cm.CommandText = "getContentAuditsByContentIDandDTS"; cm.Parameters.AddWithValue("@ContentID", criteria.ContentID); cm.Parameters.AddWithValue("@DTS", criteria.DTS); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; @@ -572,6 +577,7 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getContentAuditsByDeleteStatus"; cm.Parameters.AddWithValue("@DeleteStatus", criteria.DeleteStatus); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; @@ -647,6 +653,7 @@ namespace VEPROMS.CSLA.Library cm.Parameters.AddWithValue("@ProcedureItemID", criteria.ProcedureItemID); cm.Parameters.AddWithValue("@SelectedItemID", criteria.CurrentItemID); cm.Parameters.AddWithValue("@IncludeDeletedChildren", criteria.IncludeDeletedChildren ? 1 : 0); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; @@ -733,6 +740,7 @@ namespace VEPROMS.CSLA.Library cm.Parameters.AddWithValue("@ProcedureItemID", criteria.ProcedureItemID); cm.Parameters.AddWithValue("@SelectedItemID", criteria.CurrentItemID); cm.Parameters.AddWithValue("@IncludeDeletedChildren", criteria.IncludeDeletedChildren ? 1 : 0); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; @@ -806,7 +814,8 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getDocumentAuditsByDocID"; cm.Parameters.AddWithValue("@DocID", criteria.DocID); - using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) + cm.CommandTimeout = Database.DefaultTimeout; + using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; while (dr.Read()) this.Add(new DocumentAuditInfo(dr)); @@ -867,7 +876,8 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getEntryAuditsByContentID"; cm.Parameters.AddWithValue("@ContentID", criteria.ContentID); - using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) + cm.CommandTimeout = Database.DefaultTimeout; + using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; while (dr.Read()) this.Add(new EntryAuditInfo(dr)); @@ -928,7 +938,8 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getGridAuditsByContentID"; cm.Parameters.AddWithValue("@ContentID", criteria.ContentID); - using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) + cm.CommandTimeout = Database.DefaultTimeout; + using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; while (dr.Read()) this.Add(new GridAuditInfo(dr)); @@ -989,7 +1000,8 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getImageAuditsByContentID"; cm.Parameters.AddWithValue("@ContentID", criteria.ContentID); - using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) + cm.CommandTimeout = Database.DefaultTimeout; + using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; while (dr.Read()) this.Add(new ImageAuditInfo(dr)); @@ -1050,7 +1062,8 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getItemAuditsByItemID"; cm.Parameters.AddWithValue("@ItemID", criteria.ItemID); - using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) + cm.CommandTimeout = Database.DefaultTimeout; + using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; while (dr.Read()) @@ -1118,7 +1131,8 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getPartAuditsByContentID"; cm.Parameters.AddWithValue("@ContentID", criteria.ContentID); - using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) + cm.CommandTimeout = Database.DefaultTimeout; + using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; while (dr.Read()) this.Add(new PartAuditInfo(dr)); @@ -1171,6 +1185,7 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getPartAuditsByDeleteStatus"; cm.Parameters.AddWithValue("@DeleteStatus", criteria.DeleteStatus); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; @@ -1224,6 +1239,7 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getPartAuditsByItemID"; cm.Parameters.AddWithValue("@ItemID", criteria.ItemID); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; diff --git a/PROMS/VEPROMS.CSLA.Library/Extension/ContentExt.cs b/PROMS/VEPROMS.CSLA.Library/Extension/ContentExt.cs index a5e89098..e9407908 100644 --- a/PROMS/VEPROMS.CSLA.Library/Extension/ContentExt.cs +++ b/PROMS/VEPROMS.CSLA.Library/Extension/ContentExt.cs @@ -219,6 +219,7 @@ namespace VEPROMS.CSLA.Library cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "vesp_ListContentsByItemID"; cm.Parameters.AddWithValue("@ItemID", criteria.ItemID); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false; diff --git a/PROMS/VEPROMS.CSLA.Library/Extension/DocumentExt.cs b/PROMS/VEPROMS.CSLA.Library/Extension/DocumentExt.cs index d7a2bc6d..12d7730f 100644 --- a/PROMS/VEPROMS.CSLA.Library/Extension/DocumentExt.cs +++ b/PROMS/VEPROMS.CSLA.Library/Extension/DocumentExt.cs @@ -170,6 +170,7 @@ namespace VEPROMS.CSLA.Library cm.CommandText = "getDocumentByLibDoc"; cm.Parameters.AddWithValue("@LibDoc", criteria.LibDoc); cm.Parameters.AddWithValue("@VersionID", criteria.VersionID); + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { if (!dr.Read()) @@ -236,6 +237,7 @@ namespace VEPROMS.CSLA.Library { cm.CommandType = CommandType.StoredProcedure; cm.CommandText = "getLibraryDocuments"; + cm.CommandTimeout = Database.DefaultTimeout; using (SafeDataReader dr = new SafeDataReader(cm.ExecuteReader())) { IsReadOnly = false;